| Specification : | |
| Brand | Microtek |
| Model | ONLINE UPS MAX+ 10 KVA |
| Capacity | 10000VA / 8000W |
| DC Voltage Configuration | Default: 192 VDC | Adjustable: 216 VDC & 240 VDC |
| Topology | Double-Conversion Online UPS |
| Core Components | High-Grade IGBT & DSP Technology |
| Phase Wiring | Single Phase Input / Single Phase Output |
| Nominal Input Voltage | 208 / 220 / 230 / 240 VAC |
| Input Voltage Range (50% Load) | 110V to 300VAC (plus or minus 3%) |
| Input Voltage Range (100% Load) | 176V to 300VAC (plus or minus 3%) |
| Input Frequency Range | 46 Hz to 54 Hz |
| Input Power Factor | Greater than 0.99 @ 100% Load |
| Output Power Factor | Default: 0.8 | Optional: 0.9 with battery, 1.0 with 20-Battery |
| Nominal Output Voltage | 280 / 220 / 230 / 240 VAC |
| AC Voltage Regulation | plus or minus 1% (Battery Mode) |
| Total Harmonic Distortion (THD) | Linear Load: Less than 1% | Non-Linear Load: Less than 4% |
| Output Waveform | Pure Sine Wave |
| Transfer Time | AC Mode to Battery Mode: Zero (0 ms) | Inverter to Bypass: Zero (0 ms) |
| Efficiency (AC / Battery Mode) | 94% / 91% |
| Battery Compatibility | VRLA / SMF batteries (Adjustable: 16, 18, or 20 Nos.) |
| Maximum Charging Current | 4.0 Amperes |
| Net Weight | 33.0 Kgs |
| Dimensions (L x W x H) | 555 mm x 250 mm x 830 mm |
| Operating Noise Level | Less than 58 dB @ 1 Meter |
| System Protections | Inbuilt OVCD, Integrated TDR, Maintenance Bypass, Emergency Power Off (EPO) |
High-Performance Double Conversion: Designed with a true online double-conversion architecture and DSP controls to keep sophisticated, high-capacity equipment entirely safe from grid anomalies with zero transfer time (0 ms).
Flexible 192V-240V External Battery Bus: Supports standard 192VDC bank configurations (16 batteries), with field-adjustable software capabilities to configure for 18 or 20 batteries (216VDC/240VDC).
Wide Input Range & Unity Power Factor Option: Operates across a broad input window of 110V to 300V AC, correcting input power factor to 0.99 and providing an optional unity (1.0) output power factor with a 20-battery setup.
Smart Operation Modes & Management: Achieves up to 94% efficiency in online double-conversion mode, featuring an ECO mode for power savings, an Emergency Power Off (EPO) connector, and RS-232/USB/SNMP connectivity.
Comprehensive Protective Safeguards: Outfitted with an integrated Over Voltage Cut-Off Device (OVCD), Time Delay Relay (TDR), maintenance and static bypasses, and short-circuit protections.